Testing machine and electronic control functions – Alliance Laundry Systems 70444901R3 User Manual

Page 29

Advertising
background image

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

27

70444901

Testing Machine and

Electronic Control Functions

This feature allows the owner to run diagnostic tests

on various tumbler operations without servicing the

tumbler. The tests that are available are shown in

Table 3.
For an overview of the manual diagnostic test feature,

refer to the flowchart on the following page.

How to Enter Testing Feature

1. Enter Manual Mode. Refer to Entering the

Manual Mode.

2. Press the Up ( ) or the Down ( ) keypad until



” appears.

3. Press the Start (

) keypad. Display will

change to “



” indicating the control

software version number test.

4. Press the Up ( ) or the Down ( ) keypad to

scroll through the diagnostic test options.

How to Start Tests

To start a diagnostic test, refer to the quick reference

chart below (Table 3). Press the Start (

) keypad

when the desired test is displayed. For detailed

information on each test, read the appropriate description.

How to Exit Testing Feature

Press the Back ( ) keypad. The display will return to

Idle Mode.

Table 3

Diagnostic (Testing) Mode - Quick Reference Chart

Display

Diagnostic Mode

“”

Control Software Version

“”

Loading Door Status

“”

Lint Door Status

“”

Heater Interlock Test

“”

Fan Motor Contactor Status (  represents input status, open “” or closed “”

“”

Fan Motor Centrifugal Switch Status (  represents input status, open “” or closed “”

“ ”

Cabinet High Limit Thermostat Status (  represents input status, open “” or closed “”

“ ”

Stove High Limit Thermostat 1 Status (  represents input status, open “” or closed “”

“ ”

Stove High Limit Thermostat 2 Status (  represents input status, open “” or closed “”

“”

DIP Switch Status

“”

ICM Alarm Status

“”

ICM Reset Test

“”

External Alarm Test

“”

Dryer On Temperature Test

“”

Thermistor Temperature Test

“”

Machine Config #2 Display

“”

Machine Config #3 Display

“”

Airflow Switch Test

“”

Fan Motor Test

“”

Damper Motor Test*

“”

Reverse Motor Test*

“”

Rotation Sensor Test*

“ ”

Moisture Sensor Test (Shorted test jumper)*

“ ”

Moisture Sensor Test (Resistance test jumper)*

* = Tests only shown if enabled by the DIP switch configuration.