Error Codes

Following is a list of possible error codes for an

electronic control. Errors beginning with “



” refer to

external device Infra-red communication errors. All

other errors refer to machine errors.

Display

Description

Cause/

Corrective Action



Transmission Failure

Communication failure. Re-aim external device and try

again.



Device Time-out

Communication failure. Re-aim external device and try

again.



Invalid Command Code

Incorrect machine type. Before downloading, ensure

data is for current machine type.



Invalid or Out-of-Range Data

Incorrect machine type. Before downloading, ensure

data is for current machine type and values entered are

within the minimum and maximum limits.



CRC-16 Error

Communication failure. Re-aim external device and try

again.



Framing Error

Communication error. Re-aim external device and try

again.



Time-out Exceeded

Communication error. Re-aim external device and try

again.



Encryption Error

Incorrect machine type. Before downloading, ensure

data is for current machine type.



Invalid Wake-up or Infra-red Disabled

Communication failure or infra-red is disabled.

Manually enable infra-red on control or re-aim external

device and try again.



Shorted Thermistor Error

Remove any lint build-up around thermistor. If problem

persists, replace control or thermistor.



Open Thermistor Error

Remove any lint build-up around thermistor. If problem

persists, replace control or thermistor.

 

Airflow Switch Error (Switch Fails to

Open At End of Cycle)

Inspect lint screen and ductwork. Once error is cleared,

control will go back to previous mode of operation.

 

Airflow Switch Error (Switch Does Not

Close After Cycle Starts)

Inspect lint screen and ductwork. Cycle power to

machine (power down, then power up) or push Back ( )

keypad.

 

Airflow Switch Error (Switch Bounces

During Cycle)

Inspect lint screen and ductwork. Cycle power to

machine (power down, then power up) or push Back ( )

keypad.

Table 8 (continued)