Machine Errors

35

70444901

Auto Ignition Retry (Gas Models

Only)

If the Ignition Control Module (ICM) fails to ignite the

gas valve the ICM will send an ICM Lockout Alarm to

the control. When the control receives the ICM

Lockout Alarm it will increment the ICM Lockout

Alarm audit counter. When the error becomes fatal

(user input needed to restart the machine) the control

will increment the Heat Error audit counter and record

the Heat Error in the Last Eight Alarms Menu.
If the ICM needs to be manually reset, when the

control receives the ICM Lockout Alarm it will

display the Cycle Stopped Menu with text prompting
the user to press the Start (

) keypad to reset the

ICM. The user can continue to reset the ICM until

there are no more programmable retry attempts

(factory default is 3) or the gas ignites. On machines

equipped with an ICM that does not need to be

manually reset, when the control receives the ICM

Lockout Alarm it will turn the heat relay off for twenty

(20) seconds and then turn it back on to try and ignite

the gas. The control will continue to try and ignite the

gas until there are no more programmable retry

attempts (factory default is 3) or the gas ignites. If the

ICM fails to ignite the gas on the last attempt the

control will start the Cool Down portion of the cycle,

display the heat error message and sound the audio

signal. When the Cool Down portion of the cycle ends

the control will continue to display the error message

until power is cycled to the machine or a user presses
the Back ( ) keypad.

Air Flow Switch Errors

The control will flag an Airflow Switch Error under

several conditions. Airflow Switch Errors will be

processed differently depending upon what state the

machine was in when the error was detected.

Airflow Switch Sensed Closed While Not
In Run Mode

If an airflow switch is sensed closed 30 seconds after

entering Idle Mode, Pause Mode or End of Cycle

Mode, the control will display an error message until

power is cycled or the error clears. The cycle will not

start and all user inputs will be ignored. If the error

does clear, the control will go back to its previous

mode of operation. When this error occurs the Airflow

Switch 1 error counter will be incremented and the

error will also be saved to the Last Eight Alarms

Menu.

Airflow Switch Does Not Close After Cycle
Started

If the airflow switch does not close within 5 seconds

of the start/re-start of a cycle, the control will go to the

Cool Down portion of the cycle, display an error

message and sound the audio alarm. Once the Cool

Down portion of the cycle ends, the control will

continue to display the error message until the power
is cycled to the machine or the Back ( ) keypad is

pressed. When this error occurs, the Airflow Switch 2

error counter will be incremented and the error will

also be saved to the Last Eight Alarms Menu.

Airflow Switch Bounces During A
Running Cycle

If the airflow switch is open for at least one second,

the heat will be turned off and will remain off until the

switch is observed closed for at least 5 seconds (it is

flagged as an airflow switch bounce). If there are 5

airflow switch bounces within 5 minutes the control

will go to the Cool Down portion of the cycle, display

an error message and sound the audio signal. When the

Cool Down portion of the cycle ends, the control will

continue displaying the error message until power is
cycled or a user presses the Back ( ) keypad. When

this error occurs, the Airflow Switch Bounce Error

will be incremented and the error will also be saved to

the Last Eight Alarms Menu. The Airflow Switch

Bounce counter will be incremented for every instance

of an airflow switch bounce.

Rotation Sensor Error

If the machine is equipped with a rotation sensor, the

control will constantly monitor the input and calculate

the cylinder’s rpm. If the rpm drops to zero while the

cylinder is supposed to be spinning, the control will go

to the Cool Down portion of the cycle. The control

will display an error message and sound the audio

signal. Once the Cool Down portion ends, the control

will continue to display the error message until power

is cycled to the machine. This error will increment the

Rotation Sensor Error counter and will be saved in the

Last Eight Alarms Menu.