Fan Motor Contactor Error

If the control attempts to turn on the heater relay and

the control does not sense that the Fan Motor

Contactor is closed, the control will go to the Cool

Down portion of the cycle, display an error message

and turn on the audio signal. Once the Cool Down

portion of the cycle ends, the control will continue

displaying the error message until power is cycled or
the Back ( ) keypad is pressed. This error will

increment the Fan Motor Contactor Error counter and

will be saved in the Last Eight Alarms Menu.

Fan Motor Centrifugal Switch Error

If the control attempts to turn on the fan motor and the

fan motor contactor is sensed closed but the Fan Motor

Centrifugal Switch fails to close, the control will go

into the Cool Down portion of the cycle, display an

error message and turn on the audio signal. Once the

Cool Down portion of the cycle ends, the control will

continue displaying the error message until power is
cycled or the Back ( ) keypad is pressed. This error

will increment the Fan Motor Centrifugal Switch error

counter and will be saved in the Last Eight Alarms

Menu.

DIP Switch/Harness Index Mismatch

Error

On power up the control reads the Temperature Index

Harness value and compares that with the value of

switch 1, switch 2 and switch 3 on the DIP switch

configuration. If the result is an invalid setup the

control will not enter Idle mode and instead enter Error

Mode. The control will ignore all user inputs and

display an error message. The machine must be

powered down and the correct temperature index

harness must be installed and/or the DIP switch

configuration must be corrected.

Moisture Sensor Error

When in Idle Mode, the control will begin to monitor

the moisture sensor input. If the moisture sensor

circuitry detects a load present signal read consistently

(every second) for a ten minute period without user

input, the control will declare a load sensed. If at any

time during this sensing period, user input is detected

or the control determines that there is no load present,

it resets the load detected counter. After this ten

minute period with a consistent load sensed, the

control queues the “is dryer empty” (display “



”,



”, “



” each for two seconds) prompting

the user to answer whether the machine is currently

empty, pressing the Up ( ) or Down ( ) keypads will

toggle between yes and no. If the operator selects “no”

(display “



”), the control returns to the Idle Mode

display. If the operator selects “yes” (display “



”)

the control will increment the Moisture Sensor Error

counter and record the error in the queue of the last

eight machine errors and display the Moisture Sensor

Error (display “



”), pressing the Back ( )

keypad will clear the error. The “is dryer empty”

prompt will only appear once a day unless machine

power is cycled.