© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Testing Machine and Electronic Control Functions

33

70444901

Production Test Cycle

To Enter Production Test Cycle

1. Be certain control is in Idle Mode.
2. While pressing and holding the Down ( )

keypad with one hand, press the Back ( )

keypad with the other hand.

3. When the control enters the Production Test

Cycle, it will first display “

 

” with the “



showing the software version of the control.

4. The control will advance through the sequence of

test steps whenever any keypad is pressed, with

the exception of the Keypad Test. Refer to

Table 7 for all tests in the Production Test Cycle.

To Exit Production Test Cycle

The test will be exited when the time reaches “



” on

the control in the 10 Minute Test Cycle. Otherwise, the

control must be powered down to end the test.

NOTE: If power to the control is turned off before 10 Minute Test Cycle has ended, the cycle will be cleared

from control.

Table 7

Production Test Cycle Quick Reference Table

Display

Test Mode

Comments

“

”

Software Version

XX is the software version number.

“ ”

Control Type

2, 3, 4, 5 or 6, depending on brand.

“

Keypad Test

When a key is pressed, the control will display the number assigned to
the keypad. As each keypad is pressed, the control will display the

number assigned to it in the last digit of the display until the next key is

pressed (example, if Key 1 is pressed the control will show “ ”).
When all keypads have been pressed, the control will advance to next

step after a one second delay.

“” or

“”

Loading Door Test

The control will display the status of the loading door: “” if door

is open or “” if door is closed.

“” or
“”

Lint Door Test

The control will display the status of the lint door: “” if door is
open or “” if door is closed. Loading door must be closed.

All LEDs and

display segments

will light

Show Entire Display Mode The audio signal is turned off. Control will stay in this mode until any

key is pressed.

“

”

Machine Configuration #2
Display

 is the configuration byte value. The control will remain in this mode
until any key is pressed.

DIP Switch Configuration

The control will show the sum of all switches in the  position. The

control will remain in this mode until any key is pressed.

Degrees in 5°F
increments,

“  ”,

“  ”

Thermistor Temperature
Test

The temperature will be displayed in either Fahrenheit or Celsius,
depending on machine’s configuration (refer to Programming Control).

If control senses a shorted thermistor, SH will be displayed. If control

senses an open thermistor, OP will be displayed.

Moisture Sensor 1 Test
(Shorted)

Refer to Diagnostic Test Descriptions. Test step lasts for 15 seconds.

Moisture Sensor 2 Test

(Resistance)

Refer to Diagnostic Test Descriptions. Test step lasts for 15 seconds.

“  ”

10 Minute Test Cycle

Determines if tumbler can function in a cycle for 10 minutes. Start pad

will flash one second on and one second off. The Start pad can be used to
decrease time remaining. If Start pad is not pressed within 4.25 minutes,

the control will return to Idle Mode.

Advertising