Control Identification

11

70444901

Communication Mode

This mode is entered whenever the control is

communicating with a PDA. Refer to PC and PDA

Application User Instructions.

Cool Down Mode

The control enters the Cool Down Mode after the heat

segment of the cycle is completed. The control turns

the heater off and for steam heated units turns the

damper motor on. The cool down segment will end

once the cool down temperature has been reached or

the programmed cool down time expires, which ever

happens first.

End of Cycle Mode

The control enters End of Cycle Mode after the cool

down segment is finished. The display will toggle

between “



” and “



” for one second each

until End of Cycle Mode is exited. If the door has not

been opened or a keypad has not been pressed after

two minutes, the machine will enter Extended Tumble

Mode. This mode is exited when the door is opened or

Stop ( ) keypad is pressed. The control will then

return to Idle Mode.

Extended Tumble Mode

The Extended Tumble Mode has two portions. The

Anti-Wrinkle Tumble is entered two minutes after the

cycle has ended if the door is not opened. The cylinder

will tumble for 30 seconds every two minutes for up to

one hour.
If the door hasn’t been opened and no keys have been

pressed one hour after the Anti-Wrinkle Tumble has

ended, the control increments the Anti-Wrinkle Time

Exceeded audit counter and enters the Delayed

Tumble. The cylinder will tumble for two minutes

every 60 minutes for up to 18 hours.

Reversing Mode (reversing models only)

Models equipped with the reversing feature will rotate

in the forward direction, pause, rotate in the reverse

direction and then pause for programmable times and

segments of the cycle. Factory default rotate time is

120 seconds and reversing stop time is 6 seconds for

all cycles with reversing enabled.

Entering Diagnostic Mode From Idle Mode

When entered from the Idle Mode, the control will be

running a test selected by the user via keypad presses

or communication with a device.