Telephones and adjunct systems

360 Installing and Upgrading the Avaya G700 Media Gateway and Avaya S8300 Media Server

4. Install cross-connect jumpers to connect the pins from the 2-wire digital station to the

appropriate pins on the MM711 Media Module.

Table 20

shows a pinout chart for two-wire

stations.

5. Administer using Administrator Guide for Avaya Communication Manager, 03-300509.

Figure 23: 2500-Type Analog Telephone Wiring

Table 20: Two-Wire Station Pinout Chart

Jack Name

1

2

3

4

5

6

7

8

BRI-T

+TX

+RX

-RX

-TX

-V

GND

ADJUNCT

+Vadj

T0

-V

GNDVoice

RRVoice

+V

S0

TTVoice

DSS (QUEST)

DTX

DRX

OKdig

-V

+V

DSS (ISDN)

BRI-A

GND

TX

RX

-V

BRI-U

TX

RX

-V

GND

DCP

TX1

TX2

RX1

RX2

-V

+V

ANALOG

TIP

RING

HANDSET

-TX

+RX

-RX

+TX

Figure notes:

1. 2500-Type Analog Station

2. MM711 Analog Media Module, Position 1V301

2500wire RBP 071996

3

28

03

2

T

R

T.3

R.3

Advertising
This manual is related to the following products: