Preparing for the upgrade to R3.1 on-site

Issue 9.1 June 2006

605

Perform the following procedures if you are upgrading an S8300 that is configured as a primary
controller:

To clear alarms

To check link status

To record all busyouts

To disable scheduled maintenance

To check for translation corruption

To save translations

To stop Communication Manager on an LSP

To disable alarm origination

Note:

Note:

It is no longer necessary to disable Terminal Translation Initialization (TTI) before
an upgrade or to enable it after an upgrade.

To clear alarms

1. On the Maintenance Web Interface under Alarms, click Current Alarms.

2. If no alarms are listed, skip the next two steps.

3. If alarms are listed, click Clear All.

4. Resolve any remaining major alarms through the Communication Manager SAT.

To check link status

1. Open a SAT session.

2. Enter display communication-interface links.

Note all administered links.

3. Enter status link number for each administered link.

4. Enter list signaling group.

Note the signaling groups listed by number.

5. For each of the signaling groups listed, enter status signaling group number.

Make a note (write down) of any links that are down.

To record all busyouts

1. At the SAT prompt, type display errors and press Enter.

2. Look for type 18 errors and record (write down) any trunks that are busied out — you will

return them to their busy-out state after the upgrade.