Avaya power over ethernet (poe) switches, Available poe switch options – Avaya S8300 User Manual

Page 373

Advertising
background image

Installation and wiring of telephones and power supplies

Issue 9.1 June 2006

373

Avaya Power over Ethernet (PoE) switches

Available PoE Switch Options

Data and power are combined in a (PoE) switch and sent over a single cable, thus simplifying
power management and cabling infrastructure and saving rack space.

Avaya offers the following PoE switches:

C360 Converged Stackable Switches (C363T-PWR and C364T-PWR)

C460 Converged Multilayer Switch

P333T-PWR PoE Switch

All PoE Switches comply with the IEEE 802.3af standard.

PoE is carried over the signal leads, providing remote -48V power feeds on all 10/100 ports in
the switch/module (except on an expansion module in P333T-PWR). This allows the PD
(Powered Device) to be up to 100m away from the switch. Each port performs a standard
compatibility detection process before power is supplied to the Ethernet lines. If the PD is
removed or the link is interrupted, the port polling mechanism detects this, and power is cut off
to the port while the detection process is applied again.

The PoE switch applies power to the port only after it detects that a PD is actually connected to
the port. Each PD has a resistance range known as a "signature." The switch knows what
power has to be supplied to the device according to the signature.

Load detection is performed every 240 ms. All ports are checked for the resistance signature on
a port-by-port basis. Only non-powered ports participate in the periodic load detection. Once
power is provided to a port, it is checked periodically to see if a PD is still connected. If a PD is
disconnected from a powered port, then power is denied to the port. Disconnected ports then
automatically join the periodic load detection cycle. Each port of the switch is protected against
channel overload, short circuit, and reversed polarity that might be caused by faulty connection
between two feeding channels or by a crossed cable connection.

Switch

Maximum PoE Power (W)

Number of Powered Ports in Switch

C363T-PWR

305 24

C364T-PWR

520

48

C460

2,400 (with three PSUs)

192

P333T-PWR

200

24