Manual upgrade of an existing S8300B and G700 to R3.1

718 Installing and Upgrading the Avaya G700 Media Gateway and Avaya S8300 Media Server

To re-enable alarm origination

1. Telnet to the S8300 and log on.

2. At the command prompt, type almenable -d b -s y,

where

-d b

sets the dialout option to both (numbers)

-s y

enables SNMP alarm origination

3. Type almenable (without any options) to verify alarm origination enabled status.

To back up the system

1. Using the Maintenance Web Interface, back up the system as you did before the upgrade

selecting Save Translations and all backup sets.

If using IA770, converting switch integration from CWY1 to
H.323 (optional)

The IA770 INTUITY AUDIX Messaging application can use H.323 signaling instead of the
CWY1 board for integration with Communication Manager. The tasks for converting the CWY1
integration to H.323 are explained in Administering the S8300 and S8400 Media Servers to
work with IA 770
, 07-600788.