Agilent Technologies 6814B User Manual

Page 28

Advertising
background image

3 - Turn-On Checkout

28

Procedure

Display

Explanation

11.

Press

 or ô and scroll

to the VOLT:PROT item

VOLT:PROT 500

Display shows the overvoltage protection trip voltage
for your unit. The overvoltage protection voltage is
programmed in peak, not rms volts.

12.

Press

1, 6, 0, Enter

VOLT:PROT 160

Programs the OVP to 160 Vpeak, the rms value of
which is less than the previously set rms voltage.

0 V 60 Hz

Because the peak OVP voltage entered was less than the
rms output voltage, the OVP circuit tripped. The output
dropped to zero, CV turned off, and Prot turned on.

13.

Press

Protect

, scroll to

the VOLT:PROT item,
and press

3, 2, 0, Enter

VOLT:PROT 320

Programs the OVP to a peak value that is greater than
the rms output voltage value.
Note: You cannot clear an OVP trip until you have first
removed the cause of the condition.

14.

Press

Protect

, and

Enter

120 V 60 Hz

Executes the PROT:CLEAR command, restoring the
output. Prot turns off and CV turns on.

15.

Press

Shift

, and

Current

CURR:LEV 5

Indicates the default output current limit setting.

16.

Press

. 5

Enter

CURR:LEV .5

Sets the current limit to .5 amperes. The CC
annunciator is on, indicating that the unit is in current
limit mode and the light bulbs are dimmer because the
output voltage has dropped in its attempt to limit output
current.

17.

Press

Protect

, scroll to

the CURR:PROT item,
and press

° to select ON.

Then press

Enter

.

CURR:PROT ON

You have enabled the overcurrent protection circuit.
The circuit then tripped because of the output short. The
CC annunciator turns off and the OCP and Prot
annunciators come on. The output current is near zero.

18.

Press

Output On/Off

0.5 V 60 Hz

The output is off and the Dis annunciator turns on.

19.

Press

Protect

, scroll to

the CURR:PROT item,
press

° to select OFF,

then press

Enter

.

CURR:PROT OFF

You have disabled the overcurrent protection circuit.
The Prot annunciator turns off.

20.

Turn the unit off.

The next time the unit turns on it will be restored to the
*RST or factory default state