4 - Front Panel Operation

48

Figure 4-7. Trigger Delays and Phase Synchronization

Example

Display

j

This example uses the default trigger parameters. First, access the Voltage
menu and program the immediate and triggered voltage levels, followed by
the voltage transient mode.

Then press

Trigger Control

and

Enter

, followed by

Shift Trigger

.

VOLT 120

VOLT:T 150

VOLT:M STEP

INIT:IMMED

ô

In this example, you will set a trigger delay. First, access the Voltage menu
and program the immediate and triggered voltage levels, followed by the
voltage transient mode.

Press

Trigger Control

. Then press

ô until you access the delay parameter.

On the Entry keypad, press

. 0 1 6 7 Enter

.

Then press

Trigger Control

and

Enter

, followed by

Shift Trigger

.

VOLT 120

VOLT:T 150

VOLT:M STEP

DELAY 0

DELAY .0167

INIT:IMMED

í

This example uses the phase sync mode with no delay, but synchronized at 90.
First, access the Voltage menu and program the immediate and triggered
voltage levels, followed by the voltage transient mode.

Press

Trigger Control

. Press

ô until you access the delay parameter. If

necessary, set it to 0. Press

ô until you access the sync source command. On

the Entry keypad, press

° to obtain PHASE. Press

Enter

.

Access the Trigger Control menu again and press

ô to access the sync phase

reference parameter. On the Entry keypad, program a 90

°

phase reference by

entering

9 0 Enter

.

Then press

Trigger Control

and

Enter

, followed by

Shift Trigger

.

VOLT 120

VOLT:T 150

VOLT:M STEP

DELAY 0

SYNC:SOUR PHASE

SYNC:PHAS 90

INIT:IMMED

1

2

3

0.0167

0.000

0

90

Trigger

VOLT T level

VOLT level

VOLT T level

VOLT level

VOLT T level

VOLT level