Connections and Wiring

23

NetLinx Integrated Controllers

The FIG. 11 illustrates the relative location of the ICSNet and ICSHub Out connectors on the rear

panel.

ICSHub OUT port

The following table describes the pinout/signal information for the ICSHub OUT port located on

the rear panel of the Integrated Controller (as shown in FIG. 11).

Ethernet 10/100 Base-T RJ-45 Connections/Wiring

The following table lists the pinouts and signals associated to the Ethernet connector. FIG. 12

describes the RJ-45 pinouts, signals, and pairing for the Ethernet 10/100 Base-T RJ-45 connector

and cable.

FIG. 12 diagrams the RJ-45 cable and connectors.

FIG. 11 Location of ICSNet and ICSHub Out connectors

PORT 1

Ports

ICSNet

ICSNet

ICSHub Out

Unlike the ICSNet ports, the ICSHub connections require a specific polarity. The
IN/OUT configuration, on the hub ports, was implemented to use the same cables as
ICSNet, but these ports need TX and RX crossed. You must connect an OUT to an
IN, or an IN to an OUT port.
This is done simply to keep the polarity straight. The Hub bus is still a bus. All Hub
connections are bi-directional.

ICSHub OUT Pinouts and Signals

Pin

Signal

Color

1

RX +

orange-white

2

RX -

orange

3

------

------

4

------

------

5

------

------

6

------

------

7

TX +

brown-white

8

TX -

brown

Ethernet RJ-45 Pinouts and Signals

Pin

Signals

Connections

Pairing

Color

1

TX +

1 --------- 1

1 --------- 2

Orange-White

2

TX -

2 --------- 2

Orange

3

RX +

3 --------- 3

3 --------- 6

Green-White

4

no connection

4 --------- 4

Blue

5

no connection

5 --------- 5

Blue-White

6

RX -

6 --------- 6

Green

7

no connection

7 --------- 7

Brown-White

8

no connection

8 --------- 8

Brown