Clear Login Information

If you are unable to perform an Administrator login (because the Username
and Password information has become corrupted, or you have forgotten it,
for example), you can clear the login information with the following
procedure:

1. Power off the switch and remove the top cover from the unit chassis.

2. Short the jumper labeled Default Password on the switch’s main board.

3. Power on the switch.

When you power the switch on, the following message appears on the
LCD display:

USERNAME AND PASSWORD INFORMATION HAS BEEN CLEARED.
PLEASE POWER OFF THE SWITCH, REMOVE THE JUMPER, CLOSE
THE CASE, THEN RESTART.

4. After you start back up, the OSD login function acts exactly the way it did

the first time the switch was run (see p. 26) and you can reset passwords
for the Administrators and Users.