Equipment

Equipment in Group II, Category 2, is intended for use in areas in which explosive atmospheres caused by gases, vapors,
mists or air/dust mixtures are likely to occur.

G & D Atmospheres

In G type Explosive atmosphere (Gas, vapor, mist) equipment is suitable for use in Zone 1 areas.

In D type Explosive atmosphere (Dust) equipment is suitable for use in Zone 21 areas.

Temperature

Class

Temperature class TX based on ambient and pumped fluid temperature.

Different temperature classes can be achieved based on fluid and ambient temperatures (See chart)


Temperature Class and Maximum Liquid

Temperatures

Temperature

Class

Maximum Surface

Temperature C

Permitted

Max. Liquid or Ambient Temperature C

Comments

(Dust)

Sealed Pumps

Magnetic Drive

T1

450

260

230

Fluid temperatures are

limited by pump

construction

T2

300

225

225

T3

200

145

145

T4

135

90

90

T5

100

65

65

*T6

85

50

50

Normal class rating

* Maximum Temperature Class for Eclipse Standard/Eclipse Hypo Series Pumps is T6.