21

5. Remove the eight mounting bolts and washers (items 16, 17) holding the center housing (item 14) to the motor

spool (item 20). Remove the center housing and retaining plates (item 32).

6. Remove all o-rings from the center housing and front cover. There are two o-rings in the center housing (items 6,

15) and one in the front cover (item 9) as shown.

Figure 22

7. Remove driven magnet assembly (item 21) and containment can (item 19) from the motor spool (item 20) as

shown.

Figure 23