Maximum Sound Levels

Pump Size

Sound Level (dB)

Eclipse Standard/Eclipse Hypo 02

80

Eclipse Standard/Eclipse Hypo 05

81

Eclipse Standard/Eclipse Hypo 12

82

Eclipse Standard/Eclipse Hypo 25

83

Eclipse Standard/Eclipse Hypo 75

85

Eclipse Standard/Eclipse Hypo 125

95



Maximum Flange Loads

Pump Size

Flange Loads lb (N)

Flange Loads Ft-lb (N-m)

Eclipse Standard/Eclipse Hypo 02

25 (111)

10 (13.5)

Eclipse Standard/Eclipse Hypo 05

25 (111)

20 (27)

Eclipse Standard/Eclipse Hypo 12

25 (111)

25 (33)

Eclipse Standard/Eclipse Hypo 25

30 (133)

20 (27)

Eclipse Standard/Eclipse Hypo 75, & 125

50 (222)

25 (34)



Maximum Suction Lift (Dry or Wetted Pump)

Pump Size

Feet (m)

Eclipse Standard/Eclipse Hypo 02

3 (0.9)

Eclipse Standard/Eclipse Hypo 05

3 (0.9)

Eclipse Standard/Eclipse Hypo 12

3 (0.9)

Eclipse Standard/Eclipse Hypo 25

5 (1.5)

Eclipse Standard/Eclipse Hypo 75, & 125

5 (1.5)



NPSH Required

NPSHr = 2 ft (0.6m) at 1750rpm – All Sizes



Vacuum Systems – Flooded Suction

Maximum vacuum of 28 in-Hg (14 psi- gauge) or 0.1mm Hg (Absolute)



Solids Handling Capability

Size: 70 Microns / 0.003 inches / 0.07 mm

Maximum Concentrations: 10%

200 Mesh strainer recommended