132

Expected Malfunction


Potential Ignition Source

Measures to take to prevent the source from

becoming effective

Dry run

All moving parts in the pumps are submersed in the
pumped fluid, which acts as a lubricant and
coolant. Do not run the pump dry.

Recommend Power monitor

Recommend Flow indicator

Recommend Pressure switch

Recommend Temperature monitors

Pump bearings

Max. radial wear on bearings is .13 mm (.005 in)

Monitor pump daily when pumping non-lubricating
fluids for high temperatures at bearing bosses

Every 1000 hours inspect the pump for wear and
rebuild with a KOPKit if necessary

Typical life of the pump bearings is 2000 hours.
Regular maintenance and good record keeping will
provide a more accurate service interval

Power frame bearings

Check condition of lip seals for the power frame
every month to insure lubricant containment

High temperature

Recommend Temperature monitors

Recommend Flow indicator

Recommend Pressure switch

Recommend Power monitor