14. Align the keyway, and slide the drive magnet onto the motor shaft until the end of the motor shaft aligns with

faces of the drive magnet motor hub as shown below. Secure with the setscrew (item 26). Application of a no-
seize compound on the shaft and key will make future maintenance easier.

15. Complete assembly by replacing the assembled pump onto the motor, using care not to allow fingers to get

pinched when the magnets attract. Secure the pump to the motor with the four bolts and washers (items 22,
23). Always tighten fasteners in a progressive “crisscross” pattern.