Beijer Electronics SCOM Protocol EN User Manual

Page 112

Advertising
background image

Command Reference

112

Elektronik-Systeme Lauer, MAEN976

Response Message (Negative Acknowledge)

Under normal operation conditions, a negative acknowledge message does not con-
tain any status data in response to this command. This response message is only sent,
if there is insufficient data in the command stream.

Maximum Lr for this Command
11

Example
Set digital port output bit 1 of the monitor at address 0.7 (group 0, address 7):

The monitor at address 0.7 (group 0, address 7) acknowledged, that the requested
digital port output bit is set:

0

1

2

3

4

5

6

7...8

9

0x15

ADR

0x4C

0x41

0x55

0x02

ICHKH

0x02

0x03

ICHKD

0

1

2

3

4

5

6

7...9

10

0x07

0x07

0x4C

0x41

0x55

0x03

0x0C

0x02

0x03

0x02

ICHKD

0

1

2

3

4

5

6

7...9

10

0x06

0x07

0x4C

0x41

0x55

0x03

0x0D

0x02

0x03

0x02

0xF8

Advertising