Beijer Electronics SCOM Protocol EN User Manual

Page 51

Advertising
background image

Command Reference

Elektronik-Systeme Lauer, MAEN976

51

Response Message (Acknowledge)

Maximum Lr for this Command
13

Example 1
Set the red channel level of monitor at address 0.7 (group 0, address 7) to 190 (the
hexadecimal value of 190 is 0xBE, which is represented in ASCII as “BE” and split
into two ASCII codes as 0x42 0x45):

Monitor at address 0.7 (group 0, address 7) has acknowledged the new red channel
level 190 (0xBE):

Example 2
Query the current red channel level of monitor at address 0.7 (group 0, address 7):

Monitor at address 0.7 (group 0, address 7) has returned the current red channel level
190 (0xBE):

0

1

2

3

4

5

6

7...7+[LEN]-1

7+[LEN]

0x06

ADR

0x4D

0x43

0x43

LEN

ICHKH 0xB4

Param Ret

ICHKD

Ret

Value:

“00”: low...“FF”: high

Type:

Two-digit ASCII-encoded hexadecimal number

Length:

2

Description: Current value of the red channel

0

1

2

3

4

5

6

7...9

10

0x07

0x07

0x4D

0x43

0x43

0x03

0x1B

0xB4

0x42

0x45

0xC4

0

1

2

3

4

5

6

7...11

12

0x06 0x07 0x4D 0x43 0x43 0x05 0x1A 0xB4 0x42 0x45 0x42 0x45 0x3D

0

1

2

3

4

5

6

7...8

9

0x07

0x07

0x4D

0x43

0x43

0x02

0x1C

0xB4

0x3F

0x0C

0

1

2

3

4

5

6

7...10

11

0x06

0x07

0x4D 0x43

0x43

0x04

0x1B

0xB4

0x3F

0x42

0x45

0x85

Advertising