Command Reference

118

Elektronik-Systeme Lauer, MAEN976

Response Message (Acknowledge)

Response Message (Negative Acknowledge)
Under normal operation conditions, a device never sends a negative acknowledge in
response to this command.

Maximum Lr for this Command
11

Example
Assign command “Special functions 2” to the digital input port of the monitor at ad-
dress 0.7 (group 0, address 7):

The monitor at address 0.7 (group 0, address 7) acknowledged the new command
for the digital input port:

0

1

2

3

4

5

6

7...9

10

0x06

ADR

0x4C

0x41

0x55

0x03

ICHKH 0x02

0x06

Ret

ICHKD

Ret

Value:

0x00: Command “No operation”
0x01: Command “Set brightness”
0x02: Command “Special functions 1”
0x03: Command “Special functions 2”

Type:

Byte

Length:

1

Description: Current command assigned to the digital I/O port

0

1

2

3

4

5

6

7...9

10

0x07

0x07

0x4C

0x41

0x55

0x03

0x0C

0x02

0x06

0x02

0xF5

0

1

2

3

4

5

6

7...9

10

0x06

0x07

0x4C

0x41

0x55

0x03

0x0D

0x02

0x06

0x02

0xF5