Command Reference

24

Elektronik-Systeme Lauer, MAEN976

6.4 POT

Local Control

Enables or disables the local backlight level control. If the local backlight control is
enabled, the backlight level can be changed using the front panel buttons and by re-
mote control (serial or Ethernet interface, analog or digital input). If the local back-
light control is disabled, the backlight level cannot be changed using the front panel
buttons. It can be still changed by any remote control option.

Supported since Firmware Version
MT223 NAV-230G: 1.0

MT226 NAV-230G: 1.0-DSCALE2

Command Stream

Response Message (Acknowledge)

Response Message (Negative Acknowledge)

0

1

2

3

4

5

6

7

8

0x07

ADR

0x50

0x4F

0x54

0x01

ICHKH Local control

ICHKD

Local control

Value:

0x00: Disable local control

0xFF: Enable local control

Type:

Byte

Length:

1

Description: New local control configuration

0

1

2

3

4

5

6

7

8

0x06

ADR

0x50

0x4F

0x54

0x01

ICHKH Local control

ICHKD

Local control

Value:

0x00: Local control disabled 0xFF: Local control enabled

Type:

Byte

Length:

1

Description: Current local control configuration

0

1

2

3

4

5

6

7

8

0x15

ADR

0x50

0x4F

0x54

0x01

ICHKH Local control

ICHKD

Local control

Value:

0x00: Local control disabled 0xFF: Local control enabled

Type:

Byte

Length:

1

Description: Last local control configuration