Beijer Electronics SCOM Protocol EN User Manual

Page 29

Advertising
background image

Command Reference

Elektronik-Systeme Lauer, MAEN976

29

Response Message (Acknowledge)

Maximum Lr for this Command
13

Example 1
Set the brightness level of monitor at address 0.7 (group 0, address 7) to 200 (the
hexadecimal value of 200 is 0xC8, which is represented in ASCII as “C8” and split
into two ASCII codes as 0x43 0x38):

Monitor at address 0.7 (group 0, address 7) has acknowledged the new brightness lev-
el 130 (0x82):

Example 2
Query the current brightness level of monitor at address 0.7 (group 0, address 7):

Monitor at address 0.7 (group 0, address 7) has returned the current brightness level
200 (0xC8):

0

1

2

3

4

5

6

7...7+[LEN]-1

7+[LEN]

0x06

ADR

0x4D

0x43

0x43

LEN

ICHKH 0x81 Param Ret

ICHKD

Ret

Value:

“00”: dark … “FF”: bright

Type:

Two-digit ASCII-encoded hexadecimal number

Length:

2

Description: Current brightness value

0

1

2

3

4

5

6

7...9

10

0x07

0x07

0x4D

0x43

0x43

0x03

0x1B

0x81

0x43

0x38

0x03

0

1

2

3

4

5

6

7...11

12

0x06 0x07 0x4D 0x43 0x43 0x05 0x1A 0x81 0x43 0x38 0x43 0x38 0x7D

0

1

2

3

4

5

6

7...8

9

0x07

0x07

0x4D

0x43

0x43

0x02

0x1C

0x81

0x3F

0x3F

0

1

2

3

4

5

6

7...10

11

0x06

0x07

0x4D 0x43

0x43 0x04

0x1B 0x81

0x3F 0x43

0x38 0xC4

Advertising