Beijer Electronics SCOM Protocol EN User Manual

Page 57

Advertising
background image

Command Reference

Elektronik-Systeme Lauer, MAEN976

57

Response Message (Acknowledge)

Maximum Lr for this Command
13

Example 1
Set the blue channel level of monitor at address 0.7 (group 0, address 7) to 190 (the
hexadecimal value of 190 is 0xBE, which is represented in ASCII as “BE” and split
into two ASCII codes as 0x42 0x45):

Monitor at address 0.7 (group 0, address 7) has acknowledged the new blue channel
level 190 (0xBE):

Example 2
Query the current blue channel level of monitor at address 0.7 (group 0, address 7):

Monitor at address 0.7 (group 0, address 7) has returned the current green channel
level 190 (0xBE):

0

1

2

3

4

5

6

7...7+[LEN]-1

7+[LEN]

0x06

ADR

0x4D

0x43

0x43

LEN

ICHKH 0xB6

Param Ret

ICHKD

Ret

Value:

“00”: low...“FF”: high

Type:

Two-digit ASCII-encoded hexadecimal number

Length:

2

Description: Current value of the blue channel

0

1

2

3

4

5

6

7...9

10

0x07

0x07

0x4D

0x43

0x43

0x03

0x1B

0xB6

0x42

0x45

0xC2

0

1

2

3

4

5

6

7...11

12

0x06 0x07 0x4D 0x43 0x43 0x05 0x1A 0xB6 0x42 0x45 0x42 0x45 0x3B

0

1

2

3

4

5

6

7...8

9

0x07

0x07

0x4D

0x43

0x43

0x02

0x1C

0xB6

0x3F

0x0A

0

1

2

3

4

5

6

7...10

11

0x06

0x07

0x4D 0x43

0x43

0x04

0x1B

0xB6

0x3F

0x42

0x45

0x83

Advertising