75 lau_status_dinconfig (0x030d), Current digital input configuration, Lau_status_dinconfig (0x030d) – Beijer Electronics SCOM Protocol EN User Manual

Page 133

Advertising
background image

Command Reference

Elektronik-Systeme Lauer, MAEN976

133

6.75 LAU_STATUS_DINCONFIG (0x030D)

Current Digital Input Configuration

Returns the current digital input configuration, i.e. the command assigned to the
digital input port.

Supported since Firmware Version
MT223 NAV-230G: 1.0

MT226 NAV-230G: 1.0-DSCALE2

Command Stream

Response Message (Acknowledge)

0

1

2

3

4

5

6

7...8

9

0x07

ADR

0x4C

0x41

0x55

0x02

ICHKH 0x03

0x0D

ICHKD

0

1

2

3

4

5

6

7

8

0x06

ADR

0x4C

0x41

0x55

0x01

ICHKH

Ret

ICHKD

Ret

Value:

0x00: Command “No operation”
0x01: Command “Set brightness”
0x02: Command “Special functions 1”
0x03: Command “Special functions 2”

Type:

Byte

Length:

1

Description: Command assigned to the digital I/O port.

The commands are specified as follows:
No operation
No function assigned to the digital input pins.
Set brightness
Input bits 0…2:

Eight predefined backlight level values.
These values can be configured.

Special functions 1
Input bits 0…1:

Route the value of input pins 0 and 1 to
the output pins 0 and 1.

Input bit 2:

1: Enable analog input to backlight level

control routing.

0: Disable analog input to backlight level

control routing.

Special functions 2
Input bit 0:

1: Enable ECDIS mode.
0: Disable ECDIS mode.

Input bit 1:

1: Enable POT mode.
0: Disable POT mode.

Input bit 2:

1: Disable OSD (video controller) keys.
0: Enable OSD (video controller) keys.

Advertising