This section describes the procedures for installing the EMU-830.

EMU J

UMPER

S

ETTINGS

EMU-830s are jumper configurable for an RS-232 or RS-485 SLIP port interface. EMUs have an RS-232 factory
setting.

If you use the SLIP port to manage a shelf or shelves, you must configure the SLIP port interface before installing
the EMU-830. Do one of the following:

• For an RS-232 SLIP port interface, install the jumper on two-pin header connector P6 (

Figure 2-1

). This is the

factory default setting. Set the SLIP port baud rate as instructed in

“Configure SNMP Operation Over SLIP” on

page 3-10

.

• For an RS-485 SLIP port interface, remove the jumper from two-pin header connector P6 (

Figure 2-1

). Set the

SLIP port baud rate as instructed in

“Configure SNMP Operation Over SLIP” on page 3-10

.

Figure 2-1. Location of the SLIP Header Connector P6 on the EMU-830

Note:

Each shelf in a Multishelf TAO network must have an EMU-830 management unit installed.

Inserting and removing the EMU-830 from a shelf will not affect the operation of the DSL cards installed in
the shelf.
An EMU-830 failure will not affect the operation of the DSL cards installed in the shelf.

P6