One or more shelves can be remotely managed by connecting an external modem to the RS-232/RS-485 SLIP port.
However, when managed through the SLIP port, each shelf must be assigned a unique IP address (only one shelf is
accessed with each dial-up connection).

Figure 1-6 on page 1-7

show WorldDSL shelves managed by SNMP

through SLIP.

To connect an external modem to the RS-232/RS-485 SLIP port:

4

Connect a serial cable (with pinouts as specified below) to the EMU console port connector (DB-9F) of
the local shelf.

Figure 2-7. Modem to EMU Serial Cable Pinouts

5

Plug the other end of the cable into the serial port on the back of the modem.

6

At the back of the modem, plug a dedicated telephone line into the RJ-11 port labeled LINE or TELCO.

7

Plug the modem into an external power source and turn it on.

8

Configure the EMU modem parameters for remote alarm reporting as instructed in

“Modem Parameters

(Configure and Test Dial-out Alarm Reporting)” on page 3-14

.

Note:

See

“EMU Jumper Settings” on page 2-1

for RS-232/RS-485 SLIP port configuration.

This procedure requires the use of a 25-wire straight-through cable, with a male DB-25 connector on each
end of the cable (see

Figure 2-8 on page 2-10

).

Step

Action

1

Connect one end of the 25-wire cable to the RS-232/RS-485 (SLIP) connector on the EMS shelf.

2

Connect the other end of the cable to a standard modem.

3

If the modem has configuration switches or jumpers, set the switches or jumpers for factory default
operation. Refer to the modem user manual for more information.

4

At the back of the modem, plug a dedicated telephone line into the RJ-11 port labeled LINE or TELCO.

5

Plug the modem into an external power source and turn it on.

Step

Action

!

IMPORTANT

The modem-to-EMU serial cable must have the connector pinouts shown in
Figure 2-7 to func
tion correctly.

RD (Receive Data)

TD (Transmit Data)

GND

DCD (Data Carrier Ready)

DSR (Data Set Ready)