Chapter 3: Provisioning

LTPE-UM-3159-02

3-15

Figure 3-8. LOSW* and LOSW1 Alarm Reporting Screen

8

Test the EMU’s dial-out alarm reporting as follows:

a. Configure the shelf alarms as instructed on

page 3-16

.

b. If necessary, select the Remote Alarm Reporting menu item and press ENTER to change the set-

ting from disable (Dis) to enable (Ena). See

Figure 3-8

.

c. Disconnect and re-connect an DSL Tip or Ring lead from a shelf. The shelf modem dials the man-

agement station, which displays the following alarms on its monitor:

The alarm reporting screen in

Figure 3-8

shows that a loss of sync word occurred on both loops

(LOSW*) followed by a loss of sync word on Loop 1 only (LOSW1) and Loop 2 returning to normal
operation (that is, nothing displayed for Loop 2).

d. Disconnect and re-connect a G.703 interface cable from a shelf. The shelf modem dials the man-

agement station, which displays the following alarms on its monitor:

The alarm reporting screen in

Figure 3-9 on page 3-16

shows that a loss of signal (LOS*), power

feed open (PFO*), and loss of sync word (LOSW*) occurred on both loops.

Step

Action

!

IMPORTANT

The following steps require that you momentarily disconnect an DSL Tip or Ring lead
and then a G.703 interface cable to test remote alarm reporting. Take steps to ensure
that a customer’s service is not interrupted.

Note:

The following alarm reporting screens are examples and do not represent the alarms

displayed in all tests.