Chapter 2: Installation

September 25, 2006

2-4

LTPE-UM-3159-02

M

ULTISHELF

C

ABLE

C

ONNECTIONS

To connect the shelves using the 10BASE-T Ethernet connectors (

Figure 2-4

):

Figure 2-4. 10BASE-T Multishelf Cable Connections

Note:

Multishelf networks cannot be connected through a router because the local shelf uses UDP-

broadcast messages as a mechanism to automatically discover other shelves in the network, and routers
generally filter these broadcasts. A multishelf network is limited to 32 shelves.

Step

Action

1

Plug an RJ-45 cable into the 10BASE-T connector at the rear of each shelf.

2

Plug the other end of the RJ-45 cables into the hub/switch connecting the shelves.

Note:

The length of each RJ-45 cable cannot exceed 100 meters (328 feet).

10BASE-T
connector

RJ-45 cable

Hub/Switch