2. Technical Gas Data

a. Gas Specifications

b. Gas Connections:

Inlet connection ---- 1-1/4 inch N.P.T.

Inlet Supply Size ---- 1-1/2 inch N.P.T.

Btu/hr input --------- 750,000 (189,000 kcal/hr)

1) Natural Gas

Regulation is controlled by the dryers gas valve internal regulator. Incoming supply pressure must be

consistently between a minimum of 6.0 (14.92 mb) and a maximum of 12.0 inches water column

(29.9 mb) pressure.

2) Liquid Propane (L.P.) Gas

Dryers made for use with liquid propane (L.P.) gas have both of their gas valve's internal pressure

regulators blocked open so that the gas pressure must be regulated upstream of the dryer. The

pressure is measured at each gas valve pressure tap must be a consistent 10.5 inches water column

(W.C.) - 26.1 mb. There is no regulator or regulation provided in an L.P. gas dryer. The water column

must be regulated at the source (L.P. tank) or external regulator/regulation must be added to each

dryer.

*

D.M.S. (Drill Material Size) equivalents are as follows:

Natural Gas ........... #1 = .2280" (5.7912 mm)

Liquid Propane ..... #28 = .1405" (3.5687 mm)

T

YP E OF

G

AS

L.P.

Conversion Kit

Part

Number

MODEL

NUMBER

BTU

Per Hour

Rating

kcal/hr

Rating

Natural

Liquid Propane

Qty. D.M.S.*

Part

Number

Qty. D.M.S.*

Part

Number

MLG-200**

750,000

189,000

5

#1

140840

5

#28

140821

880754

Shaded area is stated in metric equivalent

T

YPE OF

G

AS

Natural

Liquid Propane

Manifold Pressure*

3.5 inches W.C.

8.7 mb

10.5 inches W.C.

26.1 mb

Inline Pressure

6.0 - 12.0 inches W.C.

14.92 - 29.9 mb

10.5 inches W.C.

26.1 mb

Shaded areas are stated in metric equivalents

* Measured at gas valve pressure tap when the gas valve is on.