3. For Direct Spark Ignition (DSI) System Models Manufactured With ADC Module Part No. 880815

a. Upon completing installation of the

replacement Direct Spark Ignition (DSI)

module, reestablish power to the dryer.

b. Start the drying cycle.

c. The ignition (DSI) module’s L.E.D. (light

emitting diode) indicator will be “off” for up

to approximately 1.5-seconds (prepurge

time).

d. The module’s indicator light will then turn

“green.” The gas valve will be energized

and the ignitor probe will spark for

approximately 8-seconds. The burner flame

should now be established. If the L.E.D.

on the module lights “green” continuously,

then the system is functioning properly. A

flashing “green” L.E.D. (lockout mode)

indicates that ignition flame has not been

confirmed.

e. With the burner flame on, remove the flame

sensor wire from the sense terminal of the

DSI module.

f. The burner flame must shut off and the ignition module must lockout with the DSI module’s indicator

light flashing “green.”

g Stop the drying cycle, with the flame sensor wire still removed, restart the drying cycle.

h. The ignition module must proceed through the prepurge, with the indicator light “off,” the ignition trial

time of approximately 8-seconds, with the indicator light “green,” and then proceed to lockout with the

indicator light flashing “green.”

i. Functional check of the Direct Spark Ignition (DSI) Module is complete.

1) Replace the flame sensor wire from the FS terminal to the DSI module.