American Dryer Non-Tilting Phase 5 ML-200 User Manual

Page 31

Advertising
background image

27

4. Steam Damper Air System Connections

The ML-200 is manufactured with a pneumatic (piston) damper system which requires an external supply of

compressed air. The air connection is made to the steam damper solenoid valve which is located on the outer

top, at the rear left hand corner of the dryer.

a. Air Requirements

b. Air Connection

Air connection to system --- 1/8-inch F.P.T.

c. No air regulation is provided with the dryer. External regulation of 80 PSI (5.51 bars) must be provided.

It is suggested that a regulator/filter gauge arrangement be added to the compressed air line just before

the dryer connection. This is necessary to insure that correct and clean air pressure is achieved.

5. Steam Damper System Operation

The MLS-200 steam damper, as shown in Diagram 1 on page 28, allows the coil to stay constantly charged

eliminating repeated expansion and contraction. When the damper is opened, the air immediately passes

through the already hot coil, providing instant heat to start the drying process. When the damper is closed,

ambient air is drawn directly into the tumbler (basket), allowing a rapid cool down.

Compressed Air Supply

Air Pressure

Normal

80 PSI

5.51 bars

Minimum Supply

70 PSI

4.82 bars

Maximum Supply

90 PSI

6.20 bars

Shaded areas are stated in metric equivalents

Advertising