ADTRAN MX2800 M13 User Manual

Page 138

Advertising
background image

9-14

6120

029
0L1-1

G

Section 9, Tran

sacti

on Lan

gua
ge 1 (TL1

)

M

X2
800
M13

Multip

lexer Syste

m

Manu

al

REPT

ALM

EQPT

401
(GENERAL)

MN

CTNEQPT

NSA

NEND

Controller Communication
Failure

Check the standby card for proper LED behavior (and replace if
necessary). If no problem is found, call ADTRAN Technical
Support for further troubleshooting details.

402
(CTRL A)

MN

CTNEQPT

NSA

NEND

Controller Card Failure

Replace the card which reports failure (should be indicated by a
flashing red ACT LED and the AID of the alarm).

403
(CTRL B)

402
(CTRL A)

CR

TRMT

SA

NEND

Ds3 Transmit Loss Of Signal

Replace the card for which TLOS is reported. Use the aid of the
alarm to identify the card.

403
(CTRL B)

402
(CTRL A)

MN

PROTNA

NSA

NEND

Controller Card Removed

Check to see if card was removed or reset by on-site personnel.

403
(CTRL B)

404 (PS A)

MN

PWR

NSA

NEND

Power Supply Failure

Replace the failed power supply. Use the aid of the alarm to
identify the card.

405 (PS B)

404 (PS A)

MN

MISC

NSA

NEND

Power Supply
Communication Failure

Replace the failed power supply. Use the aid of the alarm to
identify the card.

405 (PS B)

Table 9-3. MX2800 Alarm Events (Continued)

AID

Notification

Code

Condition

Type

Service

Affecting

Location

Description

Recommended Action

Advertising