Figure 3-14.trap generation menu -22, Table 3-3. trap descriptions -22, Trap descriptions – ADTRAN MX2800 M13 User Manual

Page 62

Advertising
background image

3-22

61200290L1-1G

Section 3, Configuration

MX2800 M13 Multiplexer User Manual

Figure 3-14. Trap Generation Menu

Table 3-3

provides trap descriptions.

Table 3-3. Trap Descriptions

Trap

If enabled, the unit issues a trap when...

Controller Traps

Protection Switch

The controller cards switch.

Card Removed

A controller card has been removed.

Card Failure

A controller card has failed.

Communication Fail

The controller cards can no longer communicate with each other.

Max Switches

The Max Switch Threshold is reached. For more information, refer to

Maximum Switch

Threshold

on page 3-6.

Power Supply Alarm Traps

Card Removed

The power supply card has been removed.

Malfunction

The power supply card is no longer working and the unit has switched to the backup
power supply or battery backup.

Card Failure

The power supply card has failed.

Power Low

The power supply’s output level is abnormally low.

Bat. Backup Act

Battery charger has lost its AC power source.