ADTRAN MX2800 M13 User Manual
Page 139
MX2800
M13
Mul
tip
lexe
r Syste
m
Man
ual
T
ransa
ctio
n Lang
uag
e 1 (T
L1), Secti
on 9
612
002
90L1
-1G
9-15
REPT
ALM
EQPT
404 (PS A)
MN
PWR-5
NSA
NEND
Power Supply Low
Replace the failed power supply. Use the aid of the alarm to
identify the card.
405 (PS B)
404 (PS A)
MN
HITEMP
NSA
NEND
Power Supply Temp High
Reduce the temperature of the MX2800's operating environment
or provide better ventilation.
405 (PS B)
404 (PS A)
MJ
HITEMP
NSA
NEND
Power Supply Temp Critical
Reduce the temperature of the MX2800's operating environment
or provide better ventilation.
405 (PS B)
404 (PS A)
MN
PWR-48
NSA
NEND
Power Supply Source
Failure
Check the –48 volt input indicated by the AID for a blown fuse
or disconnected/incorrect wiring.
405 (PS B)
404 (PS A)
MN
PROTNA
NSA
NEND
Power Supply Card Removed
Check to see if card was removed by on-site personnel.
405 (PS B)
Table 9-3. MX2800 Alarm Events (Continued)
AID
Notification
Code
Condition
Type
Service
Affecting
Location
Description
Recommended Action