ADTRAN MX2800 M13 User Manual

Page 139

Advertising
background image

MX2800

M13

Mul
tip

lexe

r Syste

m

Man

ual

T

ransa

ctio

n Lang

uag
e 1 (T

L1), Secti

on 9

612
002
90L1

-1G

9-15

REPT

ALM

EQPT

404 (PS A)

MN

PWR-5

NSA

NEND

Power Supply Low

Replace the failed power supply. Use the aid of the alarm to
identify the card.

405 (PS B)

404 (PS A)

MN

HITEMP

NSA

NEND

Power Supply Temp High

Reduce the temperature of the MX2800's operating environment
or provide better ventilation.

405 (PS B)

404 (PS A)

MJ

HITEMP

NSA

NEND

Power Supply Temp Critical

Reduce the temperature of the MX2800's operating environment
or provide better ventilation.

405 (PS B)

404 (PS A)

MN

PWR-48

NSA

NEND

Power Supply Source
Failure

Check the –48 volt input indicated by the AID for a blown fuse
or disconnected/incorrect wiring.

405 (PS B)

404 (PS A)

MN

PROTNA

NSA

NEND

Power Supply Card Removed

Check to see if card was removed by on-site personnel.

405 (PS B)

Table 9-3. MX2800 Alarm Events (Continued)

AID

Notification

Code

Condition

Type

Service

Affecting

Location

Description

Recommended Action

Advertising