ADTRAN MX2800 M13 User Manual

Page 152

Advertising
background image

9-28

61200290L1-1G

Section 9, Transaction Language 1 (TL1)

MX2800 M13 Multiplexer User Manual

DIAGLPBKTIMEOUT

ENUM

One of the following:
• DISABLE
• 1-MIN
• 5-MINL
• 10-MIN
• 15-MIN
• 30-MIN
• 45-MIN
• 1-HR
• 2-HR

Identifies the amount of time before a
Diagnostic Loopback will time out
• DISABLE - timeout is disabled
• 1-MIN - timeout value is one minute
• 5-MINL - timeout value is five minutes
• 10-MIN - timeout value is ten minutes
• 15-MIN - timeout value is 15 minutes
• 30-MIN - timeout value is 30 minutes
• 45-MIN - timeout value is 45 minutes
• 1-HR - timeout value is 60 minutes
• 2-HR - timeout value is 120 minutes

DIAGRESET

Y/N

Y or [N]

Resets Diagnostic Loopbacks
• Yes (Y) - reset the diagnostic loopback
• No (N) - do not reset the diagnostic

loopback

PSBATTERYLOWRLY

Y/N

Y or [N]

Identifies status of Power Supply Battery
Low alarm relay
• Yes (Y) - enables alarm
• No (N) - disables alarm

PSCHARGERFAILRLY

Y/N

Y or [N]

Identifies status of Power Supply Charger
Fail alarm relay
• Yes (Y) - enables alarm
• No (N) - disables alarm

PSFANFAILRLY

Y/N

Y or [N]

Identifies status of Power Supply Fan Fail
alarm relay
• Yes (Y) - enables alarm
• No (N) - disables alarm

PSMALFNCRLY

Y/N

Y or [N]

Identifies status of Power Supply
Malfunction alarm relay
• Yes (Y) - enables alarm
• No (N) - disables alarm

PSPOWERFAILRLY

Y/N

Y or [N]

Identifies status of Power Supply Power
Fail alarm relay
• Yes (Y) - enables alarm
• No (N) - disables alarm

Table 9-9. TL1 Editing Data Dictionary for EQPT (Continued)

Keyword

Type

Domain

Description

Advertising