ADTRAN MX2800 M13 User Manual

Page 146

Advertising
background image

9-22

61200290L1-1G

Section 9, Transaction Language 1 (TL1)

MX2800 M13 Multiplexer User Manual

FMT

ENUM

One of the following:
• CBIT
• M13

Sets framing format to match the format of
the receive signal at the network interface
• The framing format s set to CBIT
• The framing format is set to M13

LINELEN

ENUM

One of the following:
• LONG
• SHORT

Identifies Network DS3 line length
• LONG - exceeds 50 feet.
• SHORT - less than 50 feet.

RMTLPBK

ENUM

One of the following:
• DISABLE
• EITHER
• FEAC
• CBIT

Indicates whether the unit will respond to
remote loopbacks over FEAC, CBIT,
EITHER, or if remote loopbacks are disabled
• DISABLE - do not respond
• EITHER - respond over either FEAC or

CBIT

• FEAC - respond over FEAC
• CBIT - respond over CBIT

SYSCARDARLY

Y/N

Y or [N]

Identifies status of System Controller Card A
alarm relay
• Yes (Y) - enables alarm
• No (N) - disables alarm

SYSCARDBRLY

Y/N

Y or [N]

Identifies status of System Controller Card B
alarm relay
• Yes (Y) - enables alarm
• No (N) - disables alarm

SYSCARDCOMMRLY

Y/N

Y or [N]

Identifies status of System Communication
Fail alarm relay
• Yes (Y) - enables alarm
• No (N) - disables alarm

SYSCARDRLY

Y/N

Y or [N]

Identifies status of System Controller Card
alarm relay
• Yes (Y) - enables alarm
• No (N) - disables alarm

TMG

ENUM

One of the following:
• LPD
• INT

Identifies timing supply for the DS3
• LPD - loop timed
• INT - internal timing source

Table 9-6. TL1 Editing Data Dictionary for DS3 (Continued)

Keyword

Type

Domain

Description

Advertising