Provisioning the ds1 ports – ADTRAN MX2800 M13 User Manual

Page 160

Advertising
background image

A-4

61200290L1-1G

Appendix A, Acceptance Test Procedure

MX2800 M13 Multiplexer User Manual

DS2 #6

= M12(4xT1)

DS2 #7

= M12(4xT1)

NOTE

For additional information about the previous configuration, refer to

Network Interface

on page 3-4.

2. Press the

E

SC

key to get back to the main

Configuration

menu.

Provisioning the DS1 Ports

1. From the main Configuration menu, select

T1/E1 Interface

. The Configure T1/E1 Interface menu

should appear. Since there are 28 DS1 ports to configure and all of them need to be set identically dur-
ing acceptance testing, the Set Multiple provisioning feature of the MX2800 is used during this step.

To use the

Set Multiple

feature, select the attribute from the

Configure T1/E1 Interface

screen. From the

Set Multiple

screen, confirm that

First = 1

and

Last = 28

. If not, make the necessary corrections. Select

State

to toggle the

State

as necessary until the correct setting is displayed, and select

Apply settings

to

set all 28 DS1s to that mode. Press

E

SC

twice to return to the

Configure T1/E1 Interface

menu.

2. Select

T1/E1 State

. If all channels are set to

Auto Enable

(default), press

E

SC

to get back to the

Configure T1/E1 Interface

menu and proceed to the next step. If not, perform the

Set Multiple

routine

referenced above.

3. Select

T1/E1 Line Coding

. If all channels are set to

B8ZS

(default), press

E

SC

to get back to the

Configure T1/E1

Interface

menu and proceed to the next step. If not, perform the

Set Multiple

routine

accordingly.

4. Select

T1/E1 Line length

. If all channels are set correctly (

0-133

,

133-266

,

266-399

,

399-533

or

533-

655

feet

) as appropriate for the installation, proceed to the next step. If not, perform the

Set Multiple

routine accordingly.

5. Select

T1/E1Loopback Detection

.

6. Select

Set Multiple

. Set

First

to

1

,

Last

to

28

,

Loopback Detection

to

Disabled. Select Apply Settings

.

7. Press

E

SC

twice to return to the

Configure T1/E1 Interface

menu.

8. Select

T1/Circuit Protection

.

9. Select

Set Multiple

. Set

First

to

1

and

Last

to

28

. Set

Circuit Protection

to

Enabled

. Select

Apply

Settings

.

10. Press

E

SC

once and select

Protection Threshold

. Enter a value of 1 and press

E

SC

once to return to the

Configure T1/E1 Interface

menu.

11. Select

XCV Threshold

. Select

Disabled

.

12. Press the

Esc

key to get back to the main Configuration menu.

Advertising