Table 9-4. MX2800 Informational Events

AID

Notification

Code

Condition

Type

Service

Affecting

Location

Description

Recommended Action

REPT

EVT T1

101-128

EVT

BPV

NSA

NEND

Excessive DS1 Bipolar Viola-
tion

Make sure the line coding (B8ZS/AMI) is provisioned
correctly for this DS1 facility. Check the DS1 facility entering
the MX2800 for impairments which may cause line code
violations.

101-128

EVT

AIS

NSA

FEND

DS1 Line AIS (LAIS)

Check the status of this DS1 signal toward the MX2800 at
each DS1 device (for example, an intermediate device which
sees LOS on the DS1 toward the MX2800 may transmit AIS
toward the MX2800 in response).

101-128

EVT

AISUONE
S

NSA

FEND

DS1 Carrier AIS (CAIS)

If there are no DS3 or DS2 alarms reported, check the status of
the DS1 facility entering the far-end M13 multiplexer. For
example, if the far end M13 multiplexer detects LOS on the
DS1 facility, it will send DS1 AIS over the DS3 toward the
MX2800.

REPT

EVT T2

REPT

EVT T3

201-207

EVT

AIS

NSA

FEND

DS2 AIS

Check status of DS2 at the far-end M13 multiplexer.

302
(CTRL A)

EVT

AIS

NSA

FEND

DS3 Alarm Indication Signal

Check the status of the DS3 signal toward the MX2800 at each
DS3 device. (For example, an intermediate device which sees
LOS or LOF on the DS3 toward the MX2800 may transmit
AIS toward the MX2800 in response.)

303
(CTRL B)

302
(CTRL A)

EVT

BPV

NSA

NEND

Excessive DS3 Bipolar Viola-
tion

Check DS3 facility entering the MX2800 for problems which
may produce bipolar violations.

303
(CTRL B)

REPT

EVT

EQPT

401
(GENERAL)

EVT

WKSWPR

NSA

NEND

Protection Switch

If protection switch was not performed manually, check for
other alarms indicating the failure which caused the switch.

401
(GENERAL)

EVT

ESW

NSA

NEND

Excessive Protection Switch

If protection switches were not performed manually, check for
other alarms indicating the failure(s) which caused the
switches.

REPT

EVT

EQPT

402
CTRL A

EVT

PROGFLT

NSA

NEND

Software
Version
Mismatch

Reset the reported card so the new software can take effect.