SP1000 series operator’s manual

Manual SP1000 series

7

‘Withdraw’ indicates that the pumping direction is set for withdrawing. If not lit, then the pumping
direction is set for infusing. Also, the ‘Withdraw’ LED indicates that the “Volume Dispensed” refers to the
volume withdrawn. If not lit, the “Volume Dispensed” refers to the volume infused.

LED

Description

mm

Millimeters

ml

Milliliters

min

Minutes

l

Microliters

hr

Hours

Dispensed

Volume dispensed displayed

Withdraw

Pumping Direction:

Lit:

Withdraw

Not lit: Infuse

Pumping

Lit:

Motor is operating

Blinking: The Pumping Program is

paused

Not lit:

The Pumping Program is
stopped or executing a pause
Phase

6.4

Arrow and Decimal Point Keys

Each of the four digits in the display is associated with the up arrow key directly below it. When
applicable, the arrow key is used to increment the value of that digit, or advance to the next selection in a
list of functions or settings.

Each press of an up arrow key will increase the digit by 1, up to 9, and then back to 0. The arrow keys may
also be held down for continuous incrementing of numbers. Some parameters, such as the RS-232 baud
rate, scroll through a selection of values when the arrow keys are pressed. Other parameters have a fixed
range of values, such as some setup parameters that are either turned on or off. In these cases, the arrow key
will only scroll up to the maximum value for that parameter, then back to the minimum value.

When changing the pumping rate units, each press of any arrow key will change the units LEDs to the next
units selection.

When the display blinks, the new value is stored and takes affect. This will occur when a non-arrow key is
pressed or after a 2 second delay since the last key press.

6.4.1 Decimal Point Key

There are 4 decimal point positions on the LCD display. Each decimal point position is to the right of a
digit in the display. The last decimal point position, to the right of the right-most digit is not displayed,
indicating whole numbers with no decimal point.

To change the position of the decimal point, use the left-most arrow key / decimal point key (

/

). Press

and hold this key for at least 1 second and wait until the left-most digit scrolls past ‘9’ to ‘0’. While
continuing to hold this key, the decimal point will shift 1 position to the right. After the right-most decimal
point position, the decimal point will shift to the first decimal point position. Release the key when the
decimal point is in the required position.

6.5

‘Diameter’ and ‘Setup’ Key

The ‘Diameter’ key allows the syringe inside diameter to be viewed and set. While being displayed, the
‘mm’ LED is lit. With the Pumping Program stopped, momentarily pressing this key will display the

Pumping rate units are expressed using 2 LEDs:

‘ml/min’ =

ml

min
hr

l

‘ml/hr’

=

ml

min

hr

l

l/min’ =

ml

min
hr

l

l/hr’

=

ml

min
hr

l