Removing and reinstalling the rack handles – Lenovo ThinkServer RD440 User Manual

Page 103

Advertising
background image

Notes:

• Use only parts provided by Lenovo.

• Depending on the model, your server might look slightly different from the illustrations in this topic.

The EMI integrity and cooling of the server are protected by having all drive bays and PCI card slots covered
or occupied. When you install an internal drive or a PCI card, save the EMI shield or dummy tray from the
drive bay or save the PCI card slot bracket in case you later remove the device.

Attention: An unoccupied drive bay or PCI card slot without a cover, shield, dummy tray, filler, or any
other protection might impact the EMI integrity and cooling of the server, which might result in overheating
or component damage.

Removing and reinstalling the rack handles

This topic provides instructions on how to remove and reinstall the rack handles. This topic contains the
following items:

“Removing and reinstalling the rack handles for server models with twelve 3.5-inch hard-disk-drive

bays” on page 91

“Removing and reinstalling the rack handles for server models with eight 3.5-inch hard-disk-drive bays

and server models with 2.5-inch hard-disk-drive bays” on page 94

Before you begin, print all the related instructions or ensure that you can view the PDF version on another
computer for reference.

Note: Depending on the model, your server might look slightly different from the illustrations in this topic.

Removing and reinstalling the rack handles for server models with twelve 3.5-inch
hard-disk-drive bays

Attention: Do not open your server or attempt any repair before reading and understanding “Safety information”
on page iii
and “Guidelines” on page 85.

To remove and reinstall the rack handles for server models with twelve 3.5-inch hard-disk-drive bays,
do the following:

1. Remove all media from the drives and turn off all attached devices and the server. Then, disconnect all

power cords from electrical outlets and disconnect all cables that are connected to the server.

2. If the server is installed in a rack cabinet, remove the server from the rack cabinet and place it on a flat,

clean, and static-protective surface. See the Rack Installation Instructions that comes with the server.

3. Remove the server cover. See “Removing the server cover” on page 87.

4. Locate the backplane. See “Components of server models with twelve 3.5-inch hard-disk-drive bays”

on page 36.

Chapter 6

.

Installing, removing, or replacing hardware

91