Installing or replacing an internal rdx drive – Lenovo ThinkServer TS440 User Manual

Page 115

Advertising
background image

10. Align the top edge of the EMI-protective panel with the top side of the hard-disk-drive cage, and then

pivot the EMI-protective panel down until it snaps into position.

Figure 57. Installing the EMI-protective panel

11. Disconnect the SATA cable for the removed non-hot-swap hard disk drive from the system board and

save the cable for future use.

12. Close and lock the front door.

13. If you are instructed to return the old non-hot-swap hard disk drive, follow all packaging instructions and

use any packaging materials that are supplied to you for shipping.

What to do next:

• To work with another piece of hardware, go to the appropriate section.

• To complete the removal procedure, go to “Completing the parts replacement” on page 157. Then, you

might need to reconfigure RAID for your server. See “Configuring RAID” on page 57.

Installing or replacing an internal RDX drive

Attention: Do not open your server or attempt any repair before reading and understanding “Safety information”
on page iii
and “Guidelines” on page 65.

Before you begin, print all the related instructions or ensure that you can view the PDF version on another
computer for reference.

• The internal RDX drive must be installed in the upper optical drive bay.

• Depending on the model, your server might look slightly different from the illustrations in this topic.

• Use any documentation that comes with the RDX drive and follow those instructions in addition to

the instructions in this topic.

Chapter 6

.

Installing, removing, or replacing hardware

103

Advertising