background image

Figure 24. Connecting cables from the RAID card to the backplanes

To connect the mini-SAS signal cables from the RAID card to the backplanes, do the following:

• If you are using a ThinkServer RAID 700 Adapter, do the following:

1. Use one mini-SAS to mini-SAS signal cable. Connect the mini-SAS connector

3

on one end of the

cable to the ports 3-0 on the RAID card. Then, connect the mini-SAS connector

4

on the other

end of the cable to the mini-SAS signal cable connector 0 on the backplane for 2.5-inch hard disk
drives or to the mini-SAS signal cable connector on the backplane for 3.5-inch hard disk drives. The
backplane for 3.5-inch hard disk drives is installed on the lower hard-disk-drive cage.

2. If your server has more than four hard disk drives installed, use the other mini-SAS to mini-SAS signal

cable. Connect the mini-SAS connector

1

on one end of the cable to the ports 7-4 on the RAID

card. Then, connect the mini-SAS connector

2

on the other end of the cable to the mini-SAS signal

cable connector 1 on the backplane for 2.5-inch hard disk drives or to the mini-SAS signal cable
connector on the backplane for 3.5-inch hard disk drives. The backplane for 3.5-inch hard disk drives
is installed on the upper hard-disk-drive cage.

• If you are using a ThinkServer RAID 500 Adapter, do the following:

1. Use one mini-SAS to mini-SAS signal cable. Connect the mini-SAS connector

1

on one end of the

cable to the port 0 on the RAID card. Then, connect the mini-SAS connector

2

on the other end of

the cable to the mini-SAS signal cable connector 0 on the backplane for 2.5-inch hard disk drives or
to the mini-SAS signal cable connector on the backplane for 3.5-inch hard disk drives. The backplane
for 3.5-inch hard disk drives is installed on the lower hard-disk-drive cage.

2. If your server has more than four hard disk drives installed, use the other mini-SAS to mini-SAS signal

cable. Connect the mini-SAS connector

3

on one end of the cable to the port 1 on the RAID card.

Then, connect the mini-SAS connector

4

on the other end of the cable to the mini-SAS signal

cable connector 1 on the backplane for 2.5-inch hard disk drives or to the mini-SAS signal cable
connector on the backplane for 3.5-inch hard disk drives. The backplane for 3.5-inch hard disk drives
is installed on the upper hard-disk-drive cage.

Note: The location of the external connector on the RAID card differs depending on the type of RAID card.

Chapter 3

.