12. Slide the hard-disk-drive cage into the chassis from the front until it snaps into position.

Note: The following illustration shows the 3.5-inch hard-disk-drive cage. For the 2.5-inch hard-disk-drive
cage, the installation procedure is the same.

Figure 92. Installing the hard-disk-drive cage

13. Reinstall all the hot-swap hard disk drives and dummy trays (if any) in the hard-disk-drive cage. See

“Installing or replacing a hot-swap hard disk drive” on page 117.

14. Refer to your note to reconnect the cables to the backplane.

15. Reinstall the front system fan 1. See “Replacing the front system fan 1” on page 144.

16. Reinstall the front bezel. See “Removing and reinstalling the front bezel” on page 69.

17. If you are instructed to return the old hot-swap hard-disk-drive backplane, follow all packaging

instructions and use any packaging materials that are supplied to you for shipping.

What to do next:

• To work with another piece of hardware, go to the appropriate section.

• To complete the replacement, go to “Completing the parts replacement” on page 157.

Replacing the non-hot-swap power supply assembly

Attention: Do not open your server or attempt any repair before reading and understanding “Safety information”
on page iii
and “Guidelines” on page 65.

This topic provides instructions on how to replace the non-hot-swap power supply assembly. This topic
applies only to server models that come with a non-hot-swap power supply assembly.