11. Do one of the following:

• If you are installing an RDX drive, save the removed EMI-protective shield from the chassis and

plastic shield from the front bezel in the event that you later remove the drive and need the shields to
cover the drive bay.

• If you are replacing an RDX drive and are instructed to return the old RDX drive, follow all packaging

instructions and use any packaging materials that are supplied to you for shipping.

What to do next:

• To work with another piece of hardware, go to the appropriate section.

• To complete the installation or replacement, go to “Completing the parts replacement” on page 157.

Installing or replacing a 2.5-inch solid-state drive

This topic contains the following items:

“Installing a 2.5-inch solid-state drive into a 3.5-inch hard-disk-drive bay” on page 108

“Replacing a 2.5-inch solid-state drive from a 3.5-inch hard-disk-drive bay” on page 113

For a list of ThinkServer solid-state drive options, go to:
http://www.lenovo.com/thinkserver

You can install or replace a hot-swap solid-state drive without turning off the server, which helps you avoid
significant interruption to the operation of the system.

The EMI integrity and cooling of the server are protected by having all drive bays covered or occupied. The
number of the installed hard disk drives or solid-state drives in your server varies depending on the server
model. The vacant bays are occupied by dummy hard-disk-drive trays. When you install a hot-swap hard
disk drive or solid-state drive, save the removed dummy hard-disk-drive tray from the drive bay in the
event that you later remove the hot-swap hard disk drive or solid-state drive and need the dummy tray to
cover the place.

Attention: An unoccupied drive bay without any other protection might impact the EMI integrity and cooling
of the server, which might result in overheating or component damage. To maintain the EMI integrity and
cooling of the server, install a new hot-swap hard disk drive or solid-state drive as soon as you remove the
failing one or the dummy tray.

Before you begin, review the following solid-state drive installation rules:

• Follow the order of the hard-disk-drive bays when installing a solid-state drive. See “Server components”

on page 23 to locate the hard-disk-drive bays in your server.

• For RAID configuration, the solid-state drives must be the same type with the same capacity if they are

within a single RAID array. For more information, see “Configuring RAID” on page 57.

• For solid-state drives with different capacities, install the solid-state drive by following the order of the

hard-disk-drive bays as well as the order from the lowest capacity to the highest capacity.

Before you begin, print all the related instructions or ensure that you can view the PDF version on another
computer for reference.

Notes:

• Depending on the model, your server might come with 3.5-inch hot-swap hard disk drives or 2.5-inch

hot-swap hard disk drives. The illustrations in this topic are based on server models with 3.5-inch
hot-swap hard disk drives. For other models, the replacement procedure is similar.

• Depending on the model, your server might look slightly different from the illustrations in this topic.

Chapter 6

.

Installing, removing, or replacing hardware

107