Diagnostic Error Code

FRU/Action

001-276-XXX System IRQ9 failure

1. Device on IRQ9

2. System board

001-277-XXX System IRQ10 failure

1. Device on IRQ10

2. System board

001-278-XXX System IRQ11 failure

1. Device on IRQ11

2. System board

001-279-XXX System IRQ12 failure

1. Device on IRQ12

2. System board

001-280-XXX System IRQ13 failure

1. Device on IRQ13

2. System board

001-281-XXX System IRQ14 (hard disk drive) failure

1. Hard disk drive cable

2. Hard disk drive

3. System board

001-282-XXX System IRQ15 failure

1. Device on IRQ15

2. System board

001-286-XXX 001-287-XXX 001-288-XXX System Timer
failure

System board

001-292-XXX System CMOS RAM error

1. Run the Setup Utility program and re-test.

2. System board

001-293-XXX System CMOS Battery

1. CMOS Battery

2. System board

001-298-XXX System RTC date/time update failure

1. Flash the system. See “Flash update procedures”

on page 127.

2. System board

001-299-XXX System RTC periodic interrupt failure

System board

001-300-XXX System RTC Alarm failure

System board

001-301-XXX System RTC Century byte error

1. Flash the system. See “Flash update procedures”

on page 127.

2. System board

005-000-XXX Video Test Passed

No action

005-00X-XXX Video error

1. Video card, if installed

2. System board

005-010-XXX 005-011-XXX 005-012-XXX 005-013-XXX
Video Signal failure

1. Video card, if installed

2. System board

005-016-XXX Video Simple Pattern test failure

1. Video Ram

2. Video card, if installed

3. System board

005-024-XXX Video Addressing test failure

1. Video card, if installed

2. System board

005-025-XXX Video Checksum Value error

1. Video card, if installed

2. System board