Diagnostic Error Code

FRU/Action

020-197-XXX PCI test warning

1. Make sure the component that is called out is

connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 51
.

2. Re-run test.

3. Replace the component that is called out in warning

statement.

4. Replace the component under test.

020-198-XXX PCI test aborted

1. If a component is called out, make sure it is

connected and/or enabled. See Chapter 6 “Using
the Setup Utility program” on page 51
.

2. Flash the system and re-test. See “Flash update

procedures” on page 127.

3. Go to “Undetermined problems” on page 76.

020-199-XXX PCI test failed, cause unknown

1. Go to “Undetermined problems” on page 76.

2. Flash the system and re-test. See “Flash update

procedures” on page 127.

3. Replace component under function test.

020-262-XXXPCI system error

1. PCI card

2. Riser card, if installed.

3. System board

025-000-XXXIDE interface Test Passed

No action

025-00X-XXX 025-01X-XXX IDE interface failure

1. IDE signal cable

2. Check power supply voltages.

3. Reseat IDE signal cable.

4. IDE device

5. System board

025-027-XXX IDE interface Configuration/Setup error

1. IDE signal cable

2. Flash the system. See “Flash update procedures”

on page 127.

3. Reseat IDE signal cable.

4. IDE device

5. System board

025-02X-XXX 025-03X-XXX 025-04X-XXX IDE Interface
failure

1. IDE signal cable

2. Check power supply.

3. Reseat IDE signal cable.

4. IDE device

5. System board

025-195-XXX IDE interface Test aborted by user

Information only Restart the test, if necessary.

025-196-XXX IDE interface test halt, error threshold
exceeded

1. Press F3 to review the log file.

2. Restart the test to reset the log file.

Chapter 7

.

Symptom-to-FRU Index