Obtaining the master’s ip address (using dhcp) – AMX Signature Series NetLinx Integrated Controller NI-3101-SIG User Manual

Page 33

Advertising
background image

Configuration and Firmware Update

23

NI-3101-SIG Signature Series NetLinx Integrated Controller

3.

Click Done to close the Device Addressing dialog.

4.

Click Reboot (from the Tools > Reboot the Master Controller dialog) and wait for the System Master to
reboot. The STATUS and OUTPUT LEDs should begin to alternately blink during the incorporation. Wait
until the STATUS LED is the only LED to blink.

5.

Press Done once until the Master Reboot Status field reads *Reboot of System Complete*.

6.

Click the OnLine Tree tab in the Workspace window to view the devices on the System. The default
System value is one (1)

.

7.

Right-click the associated System number (or anywhere within the tab itself) and select Refresh System.
This establishes a new connection to the specified System and populates the list with devices on that
system.

8.

Use Ctrl+S to save the existing NetLinx Project with the new changes.

Obtaining the Master’s IP Address (using DHCP)

1.

Select Diagnostics > Network Addresses from the Main menu to access the Network Addresses dialog
(FIG. 21).

2.

Verify that both the System number corresponds to the System value previously assigned within the
Device Addressing tab and that zero (0) is entered into the Device field.

3.

Click the Get IP Information button to configure the on-board Master for DHCP usage and then read the
IP Address obtained from the DHCP Server.

By setting the system to its default value (#1), Modero panels that were set to
connect to the Master on another System value will not appear in the OnLine Tree
tab of the Workspace window.
For example: A Modero touch panel was previously set to System #2. The system is
then reset to its default setting of System #1 and then refreshed from within the
Workspace window. The panel will not reappear until the system is changed (from
within the System Connection page on the Modero) to match the new value and both
the Master and panel are rebooted.

Verify there is an active LAN connection on the LAN port of the NI-Series Controller
before beginning these procedures.

FIG. 21

Network Addresses dialog (for a DHCP IP Address)

System Address

reflects the value

set in the Device

Addressing tab

Used to obtain a

Dynamic

IP Address

The system value must correspond to the Device Address entered in the Device
Addressing dialog. Refer to the Setting the System Value
section on page 18 for
more detailed instructions on setting a system value.