Assigning a static ip to the netlinx master – AMX Signature Series NetLinx Integrated Controller NI-3101-SIG User Manual

Page 34

Advertising
background image

Configuration and Firmware Update

24

NI-3101-SIG Signature Series NetLinx Integrated Controller

4.

Note the obtained IP Address (greyed-out and read-only). This information is later entered into the
Master Communication Settings

dialog and used by NetLinx Studio v 2.x to communicate to the

Master via an IP. This address is reserved by the DHCP server and then given to the Master.

5.

Verify that NetLinx appears in the Host Name field (if not, then enter it in at this time).

6.

Click the Use DHCP radio button from the IP Address section (if not greyed-out).

7.

Click the Set IP Information button to retain the IP Address from the DHCP server and assign it to the
on-board Master. A popup window then appears to notify you that Setting the IP information was
successful and it is recommended that the Master be rebooted.

8.

Click OK to accept the change to the new IP/DNS information.

9.

Click the Reboot Master button and select Yes to close the Network Addresses dialog.

10.

Click Reboot from the Tools > Reboot the Master Controller dialog, and wait for the System Master to
reboot and retain the newly obtained DHCP Address. The STATUS and OUTPUT LEDs should begin to
blink alternately during the incorporation. Wait until the STATUS LED is the only LED blinking.

11.

Press Done once until the Master Reboot Status field reads *Reboot of System Complete*.

12.

Complete the communication process by continuing on to the Communicating with the NI Device via an
IP

section on page 26.

Assigning a Static IP to the NetLinx Master

1.

Select Diagnostics > Network Addresses from the Main menu to access the Network Addresses dialog
(FIG. 22).

DO NOT enter ANY IP information at this time; this step only gets the System Master
to recognize that it should begin using an obtained DHCP Address.

If the IP Address field is empty, give the Master a few minutes to negotiate a DHCP
Address with the DHCP Server, and try again. The DHCP Server can take anywhere
from a few seconds to a few minutes to provide the Master with an IP Address.

Verify that these IP values are also entered into the related fields within either the
IP Settings section of the System Connection page (on the touch panel) or within the
Address field on the web browser.

Verify that the Controller has an active LAN connection before beginning these
procedures.

FIG. 22

Network Addresses dialog (for a pre-obtained Static IP Address)

System Address

reflects the value

set in the Device

Addressing tab

Used to retain an

IP Address

Advertising